BEINING.INC / 汉语

Beining battery---FCG(Valve-Regulated Maintenance-Free Battery)

未标题-9.jpg

Features And Benefits:

l water rarely

l capacity range

l have long service life

l cycles more

l no acid mist overflows, no other equipment corrosion

l Maintenance and operation are simple and intuitive.

l little resistance

l uniformity

l application range

 

Parameter Table:

Model NO.

Nominal
Voltage
(V)

Rated Capacity( ) 20hrs/25

Approx. Weight

Dimensions(mm)

Terminal Type

kg

lbs

Length

Width

Height

Total Height

mm

inch

mm

inch

mm

inch

mm

inch

FCG12-1.2

12

1.2

0.55

1.21

98

3.86

45

1.77

52

2.05

59

2.32

T0

FCG12-2.3

12

2.3

0.90

1.98

178

7.01

34

1.34

60

2.36

66

2.60

T0

FCG12-3.3

12

3.3

1.24

2.73

134

5.28

67

2.64

60

2.36

66

2.60

T0

FCG12-4

12

4

1.35

2.97

90

3.55

70

2.76

101

3.98

106

4.17

T1

FCG12-4.5

12

4.5

1.53

3.36

90

3.54

70

2.76

101

3.98

106

4.17

T1

FCG12-5

12

5

1.70

3.74

90

3.54

70

2.76

101

3.98

106

4.17

T1

FCG12-7

12

7

2.1

4.62

151

5.9

65

2.56

94

3.70

100

3.94

T2

FCG12-9

12

9

2.50

5.50

151

5.94

65

2.56

94

3.70

100

3.94

T1

FCG12-10

12

10

3.10

6.82

151

5.9

98

3.86

94

3.7

100

3.94

T2

FCG12-12

12

12

3.35

7.37

151

5.94

98

3.86

94

3.70

100

3.94

T2

FCG12-15

12

15

4.8

10.56

181

7.13

77

3.03

167

6.57

167

6.57

T3

FCG12-17

12

17

5.00

11.0

181

7.13

77

3.03

167

6.57

167

6.57

T3

FCG12-18

12

18

5.00

11.0

181

7.13

77

3.03

167

6.57

167

6.57

T3

FCG12-20

12

20

5.50

12.1

181

7.13

77

3.03

167

6.57

167

6.57

T3

FCG12-24

12

24

7.60

16.7

166

6.54

125

6.89

166

4.92

175

4.92

T4

FCG12-26

12

26

8.1

17.8

175

6.89

166

6.54

125

4.92

125

4.92

T4

FCG12-35

12

35

10.2

22.44

196

7.7

131

5.16

155

6.1

180

7.09

T16

FCG12-33

12

33

10

22.0

196

7.70

131

5.16

155

6.10

180

7.09

T16

FCG12-35

12

35

10.2

22.44

196

7.7

131

5.16

155

6.10

180

7.09

T16

FCG12-38

12

38

12.2

26.84

197

7.73

166

6.54

174

6.85

181

7.13

T12

FCG12-40

12

40

13.0

28.7

197

7.73

166

6.54

174

6.85

181

7.13

T14

FCG12-45

12

45

13.5

29.7

197

7.73

166

6.54

171

6.73

171

6.73

T12

FCG12-50

12

50

16.2

35.6

230

9.06

138

5.43

211

8.30

224

8.82

T12

FCG12-55

12

55

16.2

35.6

230

9.06

138

5.43

211

8.30

229

9.01

T9/T16

FCG12-60

12

60

19.4

42.7

350

13.8

166

6.54

179

7.05

179

7.05

T7

FCG12-65

12

65

20.5

45.1

350

13.8

166

6.54

179

7.05

179

7.05

T9

FCG12-70

12

70

22.0

48.4

260

10.2

169

6.65

211

8.30

215

8.46

T16

FCG12-80

12

80

23.4

51.5

260

10.

169

6.65

211

8.3

215

8.46

T14

FCG12-90

12

90

27.0

59.4

307

12.1

169

6.66

211

8.31

215

8.47

T8/T16A

FCG12-100

12

100

29.8

65.56

331

13.03

173

6.81

213

8.39

233

9.17

T10

FCG12-120

12

120

36.5

80.3

407

16.0

174

6.85

209

8.23

233

9.17

T11

FCG12-150

12

150

42.5

93.5

484

19.1

171

6.73

241

9.49

241

9.49

T11

FCG12-180

12

180

56.5

124

522

20.6

240

9.45

216

8.50

240

9.45

T9

FCG12-200

12

200

60

132

522

20.6

240

9.45

216

8.50

240

9.45

T11

FCG12-220

12

220

64

141

522

20.6

240

9.45

216

8.50

240

9.45

T9

FCG12-250

12

250

73.0

161

520

20.5

268

10.55

220

8.66

243

9.57

T11

 

Model NO.

Nominal
Voltage
(V)

Rated Capacity( ) 20hrs/25

Approx. Weight

Dimensions(mm)

Terminal Type

kg

lbs

Length

Width

Height

Total Height

mm

inch

mm

inch

mm

inch

mm

inch

FCG2-100

2

100

5.6

12.3

171

6.73

71

2.80

207

8.15

227

8.94

T6

FCG2-200

2

200

13.5

29.7

172

6.77

111

4.37

329

13.0

356

14.03

T20

FCG2-300

2

300

18.8

41.4

171

6.7

151

5.9

330

13.00

366

14.4

T20

FCG2-400

2

400

26.7

58.7

210

8.27

176

6.93

329

12.96

366

14.42

T20

FCG2-500

2

500

31.0

68.2

241

9.50

172

6.8

331

13.0

366

14.4

T20

FCG2-600

2

600

38.0

83.8

301

11.9

175

6.89

331

13.0

366

14.4

T20

FCG2-800

2

800

53.0

116.6

410

16.1

175

6.89

330

13.3

365

14.4

T20

FCG2-1000

2

1000

63.0

138.9

475

18.72

175

6.90

330

13.00

356

14.03

T20

FCG2-1200

2

1200

69

152

475

18.7

175

6.89

330

12.99

356

14.02

T20

FCG2-1500

2

1500

101

223

401

15.80

351

13.83

342

13.5

369

14.54

T20

FCG2-1800

2

1800

120

264.6

401

15.80

351

13.83

342

13.47

369

14.54

T20

FCG2-2000

2

2000

120

264

401

15.8

351

13.8

342

13.51

369

14.54

T20

FCG2-2500

2

2500

165

363.8

710

27.97

352

13.87

342

13.47

369

14.54

T20

FCG2-3000

2

3000

195

429.9

710

27.97

352

13.87

342

13.47

369

14.54

T20

 

Product Overview

The German BEINING FCG series valve-regulated sealed lead-acid batteries are a high-performance product line designed for backup power and energy storage applications. This series incorporates advanced AGM technology, offering excellent high-rate discharge performance, low self-discharge, and long service life. The product range covers a complete capacity spectrum from 7Ah to 250Ah, meeting various backup power and energy storage requirements.

FCG series products feature a fully sealed construction. During charging, most of the oxygen generated inside the battery is absorbed and reduced by the plates, resulting in virtually no acid mist emission. They are safe, environmentally friendly, and can be installed in office environments or equipment rooms without the need for a separate battery room.

Core Technical Advantages

Maintenance-Free Design

The battery features a valve-regulated sealed construction. During charging, most of the oxygen generated inside is absorbed and reduced by the plates, resulting in virtually no electrolyte loss. No water addition or specific gravity checks are required throughout the entire service life, achieving true maintenance-free operation.

High Electrolyte Retention

The electrolyte is absorbed into specialized AGM separators, remaining in a non-flowing state. The battery can be used even when laid on its side, though use beyond a 90-degree tilt is not recommended. This feature enhances installation flexibility while eliminating the risk of leakage.

High Sealing Reaction Efficiency

Advanced gas recombination technology achieves a gas recombination efficiency of up to 99 percent. No acid mist is emitted during charging, making the battery safe and environmentally friendly, without polluting equipment room environments or corroding equipment.

Low Self-Discharge Rate

Using specialized high-purity lead alloy grids, the self-discharge rate is controlled within three percent per month at 20℃ ambient temperature. The battery remains usable after one year of storage at room temperature when fully charged.

Long Service Life

The battery features corrosion-resistant specialty lead-calcium alloy grids, combined with specialized separators that effectively retain electrolyte, and a strong tight assembly that compresses the positive plate active material to prevent shedding. The design float service life can reach 10 to 15 years.

Excellent High-Rate Discharge Performance

With extremely low internal resistance, the battery exhibits excellent high current discharge characteristics, meeting the demands of high current surge discharge applications.

Strong Deep Discharge Recovery Capability

The battery offers excellent deep discharge recovery capability. Even after prolonged deep discharge, as long as a full recharge is performed, there is essentially no capacity reduction, and the battery quickly returns to normal capacity levels.

Wide Temperature Operating Range

The battery operates normally across a wide temperature range, with a discharge temperature range of -25℃ to +55℃ and a charge temperature range of -10℃ to +40℃.

Charging Parameters

Parameter Specification
Float Charge Voltage 13.6V - 13.8V (25℃)
Boost Charge Voltage 14.4V - 14.8V (25℃)
Maximum Charging Current Recommended 0.15C-0.2C

Product Certifications

FCG series products meet the following standards and certifications:

  • CE Certification

  • ISO 9001 Quality Management System Certification

  • ISO 14001 Environmental Management System Certification

  • Compliant with IATA/ICAO Special Provision A67 for air transport

  • Classified as non-hazardous for ground transportation

Application Fields

FCG series products are widely used in the following fields:

  • Power Plants and Power Systems: Power generation facilities, substations, power supply, industrial applications, switch-mode power supplies

  • Communication Systems: IT and telecommunications, signal equipment, data communications

  • Rail Transit: Railway signal systems

  • Renewable Energy: Solar and wind energy storage systems

  • Uninterruptible Power Supplies: UPS and EPS systems

  • Emergency Systems: Safety lighting, emergency power supplies

  • Engine Starting: Engine starting systems

  • Marine Applications: Onboard power supply equipment

  • Specialized Equipment: Cleaning machines, electric wheelchairs, electric vehicles, golf carts

Usage Precautions

Installation Requirements

  • Install the battery in a well-ventilated, dry, clean environment

  • Avoid direct sunlight, heat sources, and corrosive gases

  • The installation environment should be free from strong vibration and shock

  • Keep batteries away from fire sources and flammable materials

  • Use batteries of the same brand, model, and batch for the same battery bank

Electrical Connections

  • Confirm correct battery polarity before connection to avoid reverse connection

  • Use appropriate connection cables with sufficient current rating

  • Use insulated connections to prevent short circuits

  • Regularly check connection points for tightness and terminal cleanliness

Storage Requirements

  • The storage environment should be dry and clean, with temperature recommended between -20℃ and 40℃

  • Fully charge batteries before storage

  • Recommended supplementary charge every 6 months for long-term storage

  • Avoid mixing with metal objects to prevent short circuits

Periodic Inspection and Maintenance

Although the FCG series is maintenance-free, periodic inspection every 6 to 12 months is recommended:

  • Check the battery case for swelling, cracks, or leakage

  • Check terminals for corrosion or looseness, keep terminal surfaces clean

  • Measure individual cell float voltage

  • Check connecting cables for aging or damage

  • Remove dust and dirt from battery surfaces

Quality and Service

FCG series products are manufactured under BEINING's strict quality management system. All products undergo comprehensive testing of voltage, capacity, internal resistance, and airtightness before leaving the factory. BEINING provides technical support services including product selection, installation guidance, and fault diagnosis.

In the Chinese market, Beijing Sorrison Technology Co., Ltd. serves as the strategic partner responsible for sales and technical service.